Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
2.4.3 Port Control
Port settings are included to give users control over State (enabled or disabled), Port
Transmission Speed, Duplex, Flow Control, Rate Control and Throughput Test.
Fig. 2.23
Table 2.12
Port number on the switch.
Check the box to allow data to be transmitted and
received through this port.
Choose from Force or Auto. See notes below.
All ports Auto- Negotiation
is enabled.
Select either 10, 100,1000(Port 9, 10 only) Mbps
Port1~Port8: 100Mbps.
Port9, Port10: 1000Mbps.
Select either Half or Full Duplex. See note below.
All ports are Full-Duplex
mode.
Either on or off “Flow Control” to avoid packet
loss when congestion occurs.
All ports flow control is
disabled.
Sets limits on its transmission rate for the
incoming and outgoing. Unit: kbps
All ports rate control is
disabled.
Click button to start test ingress and
outgoing rate of this port.
Note: The maximum rate test is limited under
98Mbps.
*Note:
- Rate Control: Outgoing and incoming values have to be set between 0 and 102400(for
100M) or 1024000(for 1000M)..
0 is to turn off rate control.
The values have to be integer multiples of 64 when rate is less than 1792Kbps. Ex: 64k,
128k .. 512k…1792Kbps.