Appendix D: Disable System Firmware
The AP (application program) firmware of MB5001C can be disabled. This function is used in the situation
that one downloaded a wrong version of firmware that caused the system crashed.
To disable the current version of firmware and prevent it from executing, please do the followings:
1. Turn the power off, open MB5001C case.
2. Short pin1 and pin2 of jumper JP1 on the right-top corner from the main board to disable AP
firmware.
3. Power on MB5001C.
4. Download the correct AP firmware to MB5001C.
5. Remove the pin 1 and pin2 of jumper JP1 to enable AP firmware.
6. Close the case and continue ones operations.