Atop-technology SW550X User manual Manual de usuario Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 125
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Atop Industrial Wireless Serial Device Server Series
SW550X
User Manual V 1.1
65
Click on the COM1 link on the left hand side.
Fig. 4. 10
Select UDP in the Link Modes.
Destination IP and Port: Specify the Begin and End IP here. Four groups of range
IPs are allowed. This is the IP address of the UDP program and the Port it is listening
to. Note that the maximum number of UDP nodes that SW550X can handle would
highly depend on the traffic load. We have tested that SW550X can handle up to 200
UDP nodes (baud rate 9600 bps, request interval 100ms, and data length 30bytes).
Enter the Local Listening Port. This is the port that SW550X should listen to. Match
this setting in the UDP program (usually called destination port in the UDP program).
For serial settings, go to Sec. 3.8.2. For Advanced settings, go to Sec. 3.8.3.
Scroll to the bottom of the page and click on Save & Apply button to save the
changes.
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 124 125

Comentarios a estos manuales

Sin comentarios