Atop-technology SE5002 User manual Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
User manual Version 1.3
ABLELink
®
Ethernet Serial Server SE5002
Copyright © 2006 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
- 16 -
Fig. 15. Link Mode-TCP server setup
Î Enter 2 on “Input choice(1~5) and enter
”(Fig. 15)
Î Input destination IP on “Please input Destination IP
” ( for instance: 10. 0. 29. 123)
Î Input destination port on “Please input Destination port
”( for instance: 666 )
1. Enter 1 for Connected always
Î Double click “Enter” key
Î Input idle time in “Please input idle time to send TCP keep-alive packet(4*10sec)
”( 2->the sending
TCP keep-alive packet period is 2*10 sec)
2. Enter 2 for Triggering by received COM port data
Î Input idle time to disconnect on “Please input idle time to disconnect( 0sec , 1~255)
” ( 0->disable
the function; 2 ->the serial Inactivity beyond 2 sec will cause disconnect)
Î Input error retrying time on “Please input waiting time for error retrying (0 minute,1~255)
( 0->disable the function; 2 ->SE5002 trying to reconnect per 2 minutes)
Î Double click “Enter” key
Î Input idle time on “Please input idle time to send TCP keep-alive packet (4*10sec)
”( 2-> sending
TCP keep-alive packet period will be 2*10 sec)
Vista de pagina 16